Water Foam Fire Sprinkler Head
• Product Name:Brass,Stainless Steel
• Size:1/2" 3/4" 1"
• Expansion:≥ 5 Times
• Installation Type:Pendent
• Working Pressure:0.3-0.7Mpa
• 25% Liquid Drain Time:≥120 S
• OEM Service:Accepted
• Delivery Terms:FOB, CFR, CIF, EXW
• Payment Mode:T/T, L/C, PayPal, Western Union
• MOQ:300 Pieces
Product category:
Enterprise Atlas:
Product Details
Product Description

Foam fire sprinkler heads are devices specifically designed for spraying air-foam mixtures. Its main function is not only to evenly spray the foam mixture onto the protected area, but more importantly, it can fully mix the foam mixture with air through specific structures (such as air intake holes, splash plates, etc.), generating and spraying a large amount of high-quality fire-extinguishing foam.
These foams cover the surface of the burning object and extinguish fires through the triple effects of suffocation (isolating oxygen), cooling (evaporating water in the foams), and isolation (preventing the evaporation of flammable vapors), especially being highly effective for Class B (liquid fires).
The Difference Between Open and Closed Types
• The outlet of the open foam nozzle is open and there are no heat-sensitive elements to seal it. It is usually composed of a nozzle body and a splash disc or deflector for forming and diffusing foam. It doesn't start automatically by itself. When a fire breaks out in the protected area, the fire alarm system is triggered or manually activated, and the control valves (such as deluger valves) open. Only then will the foam mixture flow into the pipeline network and be simultaneously sprayed out from all open nozzles, covering the entire protected area.
• Closed foam sprinkler heads: Extremely similar to the sprinkler heads of common automatic sprinkler systems, their outlets are sealed by heat-sensitive elements (such as fusible alloys or glass foam). The pipe is usually filled with a pressurized foam mixture. Only when a fire breaks out and the flames or high-temperature smoke rise near the nozzle, causing its temperature-sensing element to reach the predetermined temperature (such as 68℃, 93℃) and break, will the nozzle open and spray foam. It starts "one by one".
Product Parameter
Model Number | Working Pressure | Flow Rate | Connecting Size | 25% Liquid Drain Time |
FWS-50 | 0.7Mpa | 50 LPM | 1/2 " | ≥120 S |
FWS-70 | 0.7Mpa | 70 LPM | 3/4“ | ≥120 S |
FWS-90 | 0.7Mpa | 90 LPM | 1” | ≥120 S |
KEY WORDS:Foam Water Sprinkler,Foam Sprinkler Head,1/2 Inch Foam Sprinkler,3/4“ Foam Fire Sprinkler,Water Foam Manufacturer,Pendent Foam Fire Sprinkler,Manufacturer,Factory,Wholesale,Supplier
Product Features
Open Foam Nozzle
• Fast response speed: Once the system is started, all nozzles immediately release simultaneously, which can quickly suppress large-scale fires.
• Large coverage area: Suitable for protecting large dangerous areas.
• There will be no false spraying due to the damage of individual nozzles: because the pipes are usually empty.
• Local fire extinguishing cannot be achieved: Once activated, it will cover the entire area, which may cause unnecessary foam and water damage.
• Rely on external detection systems: It must be equipped with a reliable fire detection system (such as smoke detectors, temperature detectors) to be activated in linkage; otherwise, it cannot work.
Closed Foam Nozzle
• Automatic local fire extinguishing: It only activates at the point of fire occurrence, is highly targeted, has high fire extinguishing efficiency and causes minimal losses.
• High reliability: No external detection system is required; it operates based on its own physical characteristics.
• More economical use of water and foam: only turn on the sprinkler heads affected by the fire.
• There is a delay in response: It is necessary to wait for the heat to accumulate enough to activate the temperature-sensing element, which is slightly slower than the open system linked to the detection system.
• Not suitable for rapidly spreading fires: If the fire spreads faster than the opening speed of the sprinkler heads, the effect will be greatly reduced.
• There is a risk of misoperation or blockage: The temperature-sensing element may accidentally break due to mechanical damage or corrosion.
FAQ
Q: Can you accept sample order?
A: Yes, we accept samples with little and reasonable charge.But need customer pay sample fees and transport fees first.
Q: What is your payment terms?
A: Payment supports T/T, L/C, etc.
Q: How can l get my order?
A: We will send you the goods by UPS,DHL,FedEx,Oversea Shipment or other forwarder, all with tracking number.
Q: Why choose us?
A: With over 15 years of experience in the fire protection industry, our company has professional technical personnel and many well-known partners in the domestic market. We offer favorable prices and guarantee quality, having passed multiple certifications!
——
With more than 15 years of experience serving clients, we have developed extensive expertise and in-depth industry knowledge, enabling us to deliver reliable and effective solutions tailored to your requirements.
We provide professional technical support and customized service offerings. Our committed technical team is available to assist you with product consultation, installation guidance, and comprehensive after-sales support whenever necessary.
At Sheng Feng Fire, our professionals are dedicated to helping you select the most suitable products based on your specific needs.
Please do not hesitate to contact us for further information!
Inquiry Now
If you have any suggestions or feedback on our company, please fill in the relevant information on this page and submit it. A staff member will contact you in a timely manner, or please call us directly.