Two-Piece Fire Escutcheon Plate For Sprinkler
•Product Name:Fire Escutcheon Plate For Sprinkler
•Material :Primarily utilizing cold-rolled steel sheets (coated with fire-resistant coating) and 304/316 stainless steel, with composite fireproof materials (such as ceramic fiber boards) serving as innovative supplements.
•Size :Pendent (Diameter 60-90mm × Thickness 5-8mm), Sidewall (Length 70-100mm × Width 40-60mm × Thickness 5-8mm), and Upright (Diameter 80-110mm × Thickness 5-8mm)
•Nominal Pressure :0.10-0.60 MPa(15-87 psi)
•Operating Temp :Cold-rolled steel coated escutcheons cover a temperature range of -40°C to 120°C, stainless steel escutcheons extend to -60°C to 200°C, and ceramic fiber board escutcheons support -200°C to 1000°C.
•OEM Service:Accepted
•Delivery Terms:FOB, CFR, CIF, EXW
•Payment Mode:T/T, L/C, PayPal, Western Union
Product category:
Enterprise Atlas:
Product Details
Product Description

What is a Two-Piece Fire Escutcheon Plate?
Two-piece escutcheon is an assembly consisting of two separate parts that snap or lock together around a sprinkler head and its pipe. Its primary function is to cover the irregular or oversized hole in the ceiling or wall where the sprinkler pipe comes through, providing a clean, finished appearance.
Two-Piece Fire Escutcheon Plate is a specific type of trim ring used with exposed fire sprinklers, designed for versatility and ease of installation, particularly in retrofit or renovation projects.
Technical Paramter
| Style | Single piece | Double pieces | Double pieces | Double pieces |
| Model | A | B | C | D |
| Dimension(mm) | Dia:68.2 Height:2.0 | Dia:72.5 Height:12.2 | Dia:73.4 Height:29 | Dia:74.5 Height:25.7 |
| Nominal Diameter (mm) | DN15&DN20 | |||
| Connecting Threaded (Inch) | 1/2" & 3/4" | |||
| Surface | Chrome finished,or white,blue painting | |||
| Material | Iron or stainless steel | |||
Key Components and How It Works

1. The Two Pieces:
Base Ring / Ceiling Plate: This is the part that sits flush against the ceiling. It often has a small groove or clip.
Cover Ring / Finishing Trim: This is the decorative, visible piece. It snaps into or onto the base ring, concealing the hole and the connection between the two parts.
2. The Installation Advantage:
Unlike a solid, one-piece escutcheon that must be threaded onto the sprinkler pipe before the sprinkler head is installed, a two-piece design can be installed after the sprinkler and pipe are already in place.
The base ring is placed around the pipe, and then the decorative cover is snapped on from below. This makes it ideal for situations where disassembling the sprinkler is difficult or undesirable.
Features
The Two-Piece Fire Escutcheon Plate For Sprinkler is a fire protection accessory specifically designed for sprinklers, achieving a balance between efficient fire isolation and convenient installation/maintenance through its "two-piece structure." Its core features are as follows:
1.Modular two-piece design: Enables flexible adaptation and simplified installation;
2.High fire resistance performance: Blocks flames, provides thermal insulation, and delays flame spread;
3.Thermal response compatibility: Does not interfere with sprinkler function and ensures timely activation;
4.Durability and impact resistance: Ensures long-term stability and resistance to environmental erosion;
5.Aesthetic and decorative integration: Features an invisible design that enhances spatial texture.
Product Parameter
| Material : | Primarily utilizing cold-rolled steel sheets (coated with fire-resistant coating) and 304/316 stainless steel, with composite fireproof materials (such as ceramic fiber boards) serving as innovative supplements. |
| Size : | Pendent (Diameter 60-90mm × Thickness 5-8mm) Sidewall (Length 70-100mm × Width 40-60mm × Thickness 5-8mm), and Upright (Diameter 80-110mm × Thickness 5-8mm) |
| Nominal Pressure : | 0.10-0.60 MPa(15-87 psi) |
| Channel Design : | Full Port Straight Through Type |
| Working Media : | water |
| Operating Temp : | Cold-rolled steel coated escutcheons cover a temperature range of -40°C to 120°C, stainless steel escutcheons extend to -60°C to 200°C, and ceramic fiber board escutcheons support -200°C to 1000°C. |
FAQ
Q: Can you accept sample order?
A: Yes, we accept samples with little and reasonablecharge.But need customer pay sample fees and transportfees firest.
Q: What is your payment terms?
A: Payment supports T/T, L/C, etc.
Q: How can l get my order?
A: We will send you the goods by UPS,DHL,Fedex,OverseaShipment or other forwarder, all with tracking number.
Q: Why choose us?
A; With over 10 years of experience in the fire protectionindustry, our company has professional technical personne!and many well-known partners in the domestic market. Weoffer favorable prices and guarantee quality, having passedmultiple certifications!
——
We serve customers for over 10 years — so we’ve got the knowledge and industry experience to help you get it right.Professional technical support, intimate service experience We have a professional technical support team, at any time to provide you with product consultation, installation guidance and after-sales service.
Let the professionals at Sheng Feng Fire help you select the products that meet your exact needs.
Welcome to inqury us!
KEY WORDS: sprinkler plates,fire sprinkler head,Sprinkler excutcheon plates
Inquiry Now
If you have any suggestions or feedback on our company, please fill in the relevant information on this page and submit it. A staff member will contact you in a timely manner, or please call us directly.