Standard Response Upward and Downward Sprinklers (68°C, K80)(ZSTZ80-68℃ RA1325)( ZSTX80-68℃ RA1314)
● Valve Body Material:Brass / Stainless Steel
● Temperature Rating: 68℃±3℃
● Operating Temperature: 68℃±3℃ (Glass Bulb Type); 68℃±5℃ (Fusible Alloy Type)
Working Pressure Range: 0.1–1.2 MPa (0.1–12 bar)
● OEM Service:Accepted
● Delivery Terms:FOB, CFR, CIF, EXW
● Payment Mode:T/T, L/C, PayPal, Western Union
Product category:
Enterprise Atlas:
Product Details

Product formation
Standard Response Upward/Downward Sprinklers (68°C, K80) are medium-response, general-purpose sprinklers in automatic fire sprinkler systems. Triggered by a temperature-sensitive element, they uniformly spray water at specific angles (upward sprinklers spray downward, downward sprinklers spray upward) to achieve initial fire control and suppression. Designed for conventional commercial and industrial scenarios, they balance response speed and water distribution uniformity. Their universal design (K80 flow rate, 68°C temperature) and adaptability to multiple installation directions make them
one of the most commonly used sprinkler types in fire protection projects, significantly enhancing system cost-effectiveness and fire suppression efficiency.
KEY WORDS: Automatic Fire Sprinkler System Sprinklers (68°C, K80),K80 Flow Coefficient Sprinklers, Standard Response Speed Sprinklers,68°C Action Temperature Sprinklers,
Other Classifed Products:
Fire Hose Categories, Fire Sprinkler System, Fire Protection Valve , Fire Hose Reel&Cabinet , Fire Foam Equipment,Fire Nozzle and Fire Monitor , Fire Hydrant , UL/FM Fire Fighting Equipment , Brass Valve Categories , Fire Extinguisher Series .
Product features
Standard Response Upward/Downward Sprinklers (68°C, K80) are medium-response, general-purpose sprinklers in automatic fire sprinkler systems. Their key features are as follows:
- Standard Response Design: Balances "timely fire control" with "stable reliability", making it the optimal choice for conventional commercial and industrial scenarios.
- Precise Action Temperature: 68°C ± 3°C, matching the initial smoldering temperature of common combustibles (e.g., wood, paper, fabric, typically 50–80°C). It triggers water spray beforethe fire escalates, enabling "early intervention".
- Stable Water Distribution: Features a smooth flow characteristic curve, unaffected by pipe network pressure fluctuations (0.1–1.2 MPa), ensuring consistent spray coverage.
- Bidirectional Installation: Adaptable to multiple scenarios—upward sprinklers spray downward, downward sprinklers spray upward—to suit different space needs.
- Low-Maintenance Construction: Valve body made of corrosion-resistant material, paired with long-lasting seals, reducing upkeep costs over its service life.
Product Parameters
| Component | Details |
| Valve Body Material | - Material: Brass / Stainless Steel |
| - Connection Thread: NPT 1/2" (US Standard) / G 1/2" (BS Standard) | |
| - Type: Glass Bulb (Mainstream) / Fusible Alloy | |
| Temperature-Sensing Element Material | - Temperature Rating: 68℃±3℃ |
| - Liquid Filling in Glass Bulb: Alcohol/Ether Mixture (Stable Thermal Expansion Coefficient) | |
| Sprinkler Deflector Material | - Material: 304 Stainless Steel / Brass (Surface Chromium Plating for Corrosion Resistance) |
| - Structure: Stamped Corrugated/Radial Slots (Aperture: 0.5–1.0mm) | |
| Seal Material | - Material: Nitrile Butadiene Rubber (NBR, Shore Hardness 70±5) |
| - Structure: Valve Disc O-Ring + Sprinkler Deflector Gasket | |
| Response Time Index (RTI) | - 80–350 m·s⁰·⁵ (Standard Response Rating) |
| - (Note: Smaller RTI means faster response. Fast-response sprinklers have RTI ≤50; slow-response sprinklers have RTI ≥350) | |
| Operating Temperature | - 68℃±3℃ (Glass Bulb Type); 68℃±5℃ (Fusible Alloy Type) |
| - (Fully open within 3–5 seconds after activation) | |
| Flow Coefficient (K) | - K80 (Definition: At 1.0 bar pressure, flow rate = K × √pressure = 80 × √1 = 80 L/min) |
| - (Flow rate fluctuation ≤5% when pressure is 0.1–1.2 MPa) | |
| Spray Angle & Coverage Radius | - Upright Type: Downward spray angle 45°–60°; Coverage radius 3.6m (wetted area ≥8m²) at 2.5m installation height |
| - Pendent Type: Upward spray angle 30°–45°; Coverage radius 2.8m (wetted area ≥6m²) at 2m installation height | |
| Working Pressure Range | - 0.1–1.2 MPa (0.1–12 bar) |
| - (Recommended working pressure: 0.3–0.8 MPa, balancing flow rate and spray stability) | |
| Start-Up Time | - From ambient temperature reaching operating temperature to fully open: ≤10 seconds (standard response requirement) |
| - (Glass bulb type ≤8 seconds; fusible alloy type ≤10 seconds) |
*The specific parameters are subject to customization.
FAQ
Q: Can you accept sample order?
A: Yes, we accept samples with little and reasonable charge.But need customer pay sample fees and transport fees first.
Q: What is your payment terms?
A: Payment supports T/T, L/C, etc.
Q: How can l get my order?
A: We will send you the goods by UPS,DHL,FedEx,Oversea Shipment or other forwarder, all with tracking number.
Q: Why choose us?
A; With over 15 years of experience in the fire protection industry, our company has professional technical personnel and many well-known partners in the domestic market. We offer favorable prices and guarantee quality, having passed multiple certifications!
——
We serve customers for over 15 years — so we’ve got the knowledge and industry experience to help you get it right.Professional technical support, intimate service experience We have a professional technical support team, at any time to provide you with product consultation, installation guidance and after-sales service.
At Sheng Feng Fire, our professionals are dedicated to helping you select the most suitable products based on your specific needs.
Let the professionals at Sheng Feng Fire help you select the products that meet your exact needs.
Welcome to inquiry us!
Inquiry Now
If you have any suggestions or feedback on our company, please fill in the relevant information on this page and submit it. A staff member will contact you in a timely manner, or please call us directly.